Dongli Kechuang inverter terminal pulse setting frequency

2026-04-06 05:43:30 · · #1

Dongli Kechuang inverter terminal pulse setting frequency

High-speed pulse input terminals can only be selected as HDI. Input: The maximum received pulse frequency is 50kHz . The following are the parameter settings.

Parameter number

Parameter setting value

illustrate

F00.02

4

HDI pulse input

F06.00

0 (default)

High-speed pulse input

F06.28

0.00kHz ( default value, set as needed )

HDI lower limit frequency

F06.29

0.0% ( default value, set as needed )

HDI lower limit frequency setting

F06.30

50.00kHz ( default value, set as needed )

HDI upper limit frequency

F06.31

100.0% ( Default value, set as needed )

HDI upper frequency limit setting

F06.32

0.10s ( default value, adjust as needed )

HDI frequency input filtering time