Summary of Super Passwords for Various Frequency Converters

2026-04-06 06:58:02 · · #1

1. Delta inverter super code - B series: 57522

Delta inverter's super code - H series: 33582

The universal code for Delta S1 series inverters: 57522

2. The super password for the Orui frequency inverter (formerly Huifeng frequency inverter) is: 1888

1500-G, 1500-P, 1000-G, and 200-G are all compatible.

3. Shuopu Inverter Advanced Menu

P301 Input 321

Enter 11 in A000 to refresh the program.

P301 Input 321

Enter 9 in A000 to access the menu.

E001, Input machine G,P

E002 Rated Voltage

E003 Rated Current

E004 Voltage Correction

E005 remains unchanged.

E006 Current Correction

4. How to refresh settings on the PI2000

(1) Set C01 to 222 and enter P14

(2) Set P14 to refresh 3 pairs of CPUs, then PI2000 will be displayed.

Set C01 to 222 to enter the P14 parameter setting. Set P14 to 2. Set P01 to set the model to G or F. Set P02 to set the inverter voltage to 380V. Set P03 to set the inverter rated current. Set P04 to set the voltage display. Set P05 to set the current display.

5. INVT Universal Password 50112

For models CHV, CHE, and CHF, regardless of how many passwords are set in parameter P7-00, the universal password is: 50112.

6. If you can't log in without the password, for the Mitsubishi 740, just unplug the panel and plug it back in.

7. The password for Emerson TD3000 is 8888.

The password for Emerson TD3300 2002

8. The universal password for Xilin frequency converters: 6860 (it used to be, try it now).

9. ABB ACS600 frequency converter complete parameter password

NAMC main control board parameter settings:

(1) Enter the password in parameter 16.03: 2303

(2) The 102.01 parameter is set to: false

You can access and configure all main control board parameters.

10. The password for the Yaskawa G5 inverter is displayed in section A1-04. Navigate to this parameter, then simultaneously press and hold the MENU and RESET buttons for 10 seconds to view the password. After viewing the password, navigate to section A1-05 and enter the password to modify the parameters.

11. For the Yaskawa G7 password, when A1-04 is displayed, press RESET while pressing MENU to display the password setting A1-05. Then enter this password into A1-04, and you can then use this password to log in.

12. The procedure for restoring the parameters of the Hitachi J300 inverter to factory settings is as follows: rename a multi-function terminal to the "initialization" function (parameters C0-C7), then short-circuit this terminal with the common terminal "CM1" (or P24), and then power off and then power on the inverter.