Share this

OKE Inverter Function Data Explanation Series, Lecture 4: P03 Group Motor Parameter Group

2026-04-06 05:11:47 · · #1

P03 group motor parameter group

1

P03.00

Inverter type

0: Type G machine (constant torque load model)

1: P-type unit (for fan and pump loads)

Model settings

64

2

P03.01

Motor rated power

0.4~900.0KW

Model settings

64

3

P03.02

Motor rated frequency

0.01Hz~P01.07 (maximum frequency)

50.00Hz

64

4

P03.03

Motor rated speed

0~36000rPm

Model settings

64

5

P03.04

Motor rated voltage

0~460V

Model settings

64

6

P03.05

Motor rated current

0.1~2000.0A

Model settings

64

7

P03.06

Motor stator resistance

0.001~65.535Ω

Model settings

64

8

P03.07

Motor rotor resistance

0.001~65.535Ω

Model settings

65

9

P03.08

Motor stator and rotor inductance

0.1~6553.5mH

Model settings

65

10

P03.09

mutual inductance between motor stator and rotor

0.1~6553.5mH

Model settings

65

11

P03.10

Motor no-load current

0.01~655.35A

Model settings

65

12

P03.11

Motor parameter self-learning

0: No operation

1: Comprehensive parameter self-learning

2: Parameter static self-learning

0

65

Serial Number

code

Description of LED/OLED

Keyboard display

Set range

Factory settings

Change

Reference Page

Read next

Analysis, Design and Implementation of Control System for Warehouse-type Intelligent Robotic Parking Equipment

Abstract : This paper mainly introduces the main mechanical structure of the warehouse-type robot parking equipment and ...

Articles 2026-02-22